Controller

컨트롤러

1) NA TYPE

This controller mainly used in outdoor/internal environments.
(OD type is only detects to chemical not water)

Model AMS-NA-01F
Type Chemical(acid, alkali) type
*Option : Conductive liquid detectable (contact us.)
Size 110*75*20mm
Reaction speed Can be set directly in 1 second
Communication specification Relay Contact output (Leak, Broken Individual)–COM, NO, NC(dry contact)
Remarks replacement product for AMS-OD-FND-1CH

Model AMS-NA-02F
Type Chemical(acid, alkali) type
*Option : Conductive liquid detectable (contact us.)
Size 114x 99 x 17.6mm
Reaction speed Can be set directly in 1 second
Communication specification Relay Contact output (Leak, Broken Individual)–COM, NO, NC(dry contact)
Remarks replacement product for AMS-OD-FND-2CH

Model AMS-NA-01M
Type Chemical(Acid, Alkali) sensor (Can be used in outdoor enviorment_Water and chemical fractionation detection) *Option : Conductive liquid detectable (contact us.)
Size 120*110*30mm
Reaction speed Can be set directly in 1 second
Communication specification RS-485, Relay Contact output (Leak, Broken Individual output-dry contact)

Model AMS-NA-05M
Type - Chemical(Acid, Alkali) sensor (Can be used in outdoor enviorment_Water and chemical fractionation detection) *Option : Conductive liquid detectable (contact us.)
Size 160*115*30mm
Reaction speed Can be set directly in 1 second
Communication specification Ethernet, RS-485, Relay Contact output (Leak, Broken Individual output-dry contact)

Model AMS-NA-10M
Type Chemical(Acid, Alkali) sensor (Can be used in outdoor enviorment_Water and chemical fractionation detection) *Option : Conductive liquid detectable (contact us.)
Size 190*115*30mm
Reaction speed Can be set directly in 1 second
Communication specification Ethernet, RS-485, Relay Contact output (Leak, Broken Individual output-dry contact)

Model AMS-NA-01ME
Type Dielectric constantdetection
Size 120 x 110 x 30mm
Reaction speed Can be set directly in 1 second
Communication specification RS-485, Relay Contact output (Leak, Broken Individual output-dry contact)

Model AMS-NA-05ME
Type Dielectric constantdetection
Size 160 x 125 x 40mm
Reaction speed Can be set directly in 1 second
Communication specification Ethernet, RS-485, Relay Contact output (Leak, Broken Individual output-dry contact)

Model AMS-NA-10ME
Type Dielectric constantdetection
Size 147 x 103 x 30mm
Reaction speed Can be set directly in 1 second
Communication specification Ethernet, RS-485, Relay Contact output (Leak, Broken Individual output-dry contact)

2)IG TYPE (Inorganic Sensing type)

The controller that detects liquids (water,chemical etc.) is used in indoor environments.

Models AMS-NI-10C

Type Conductive liquid type

Size (㎣) 190*115*30

Reaction speed ~Within 1 second(Immediate detection)
Communication Output Ethernet, RS-485, Relay – COM, NO, NC(dry contact)

Model AMS-NI-01C
Type Conductive liquid type
Size 75*65*30
Reaction speed ~Within 1 second(Immediate detection)
Communication specification Relay Contact output (Leak, Broken Individual output)– COM, NO, NC(dry contact)

3)PH TYPE

Model AMS-PH-01M
Type 1channel Conductive liquid type
Size 120*110*30
Reaction speed Can be set directly by 1 second
Communication specification Relay contact, RS-485, Analyst (with AMS-ND-03S)

Model AMS-PH-05M
Type 5channel Conductive liquid type
Size 120*110*30
Reaction speed Can be set directly by 1 second
Communication specification Ethernet, Relay contact, RS-485, Analyst (with AMS-ND-03S)

Model AMS-NH-01M
Type Conductive liquid type
Size 120*110*30
Reaction speed Can be set directly by 1 second
Communication specification RS-485, Relay Contact output (Leak, Broken Individual output-dry contact)

4)Monitoring System(ALMS)

Sensor system layout Themonitoring system (ALSM) is a program that can manage and monitor leak detection sensors
in real time, helping comprehensively manage leak sensors installed in large areas. Immediately after
the leak/short circuit occurs, the event is communicated to the user to enable initial response to the
accident and to accurately locate the accident in each sensor.

Monitoring System Program 1. Sensor-Connector (Start Connector) -Controller- (RS485/Ethernet)-Monitoring System/Kiosk (ALMS)
Situation Room
2. When a leak alarm occurs, real-time text data can be received and history management is easy.
3. PossessAmus self-monitoring system, can be mapped to each site